What was found
DURING MAINT"A"CHECK, EMERGENCY LIGHT TEST FAILED WITH "EMER LT BAT LO" ALERT ON DISPLAY. MX R & R EMERGENCY BATTERY POWER SUPPLY IAW AMM 33-51-01-4 TEST PASSED AMM 33-51-01-5.