As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD PIT EXISTING "J " CHANNEL REPAIR AT STA 824 BETWEEN LONGERON 51L AND LONGERON 51R REQUIRES EVALUATION. VISUALLY INSPECTED REPAIR - FOUND NOT IN COMPLIANCE WITH APPROVED DATA. REMOVED OLD REPAIR AND INSTALLED NEW REPAIR IAW SRM 53-30-00, FIG 5, VOL I. THIS IS A CLASS "B" REPAIR WITH A VISUAL INSPECTION DUE AT 43,510 CYCLES.