What was found
NR 2 ENG OIL FILTER LEVEL II ALERT. INFLT SHUT DOWN AS PER FLT CREW WITH LEVEL II ALERT, ENG HAD NORMAL OIL PRESSURE. INSPECTED FILTER ELEMENT FOR CLOGGING, ELEMENT FOUND CLEAN AND NOT CLOGGED. INSTALLED NEW FILTER ELEMENT AS PER MM 79, RAN ENG AS PER JRH, PERFORMED LEAK CHECK. INDICATION NORMAL AT IDLE & ACCELL. NO OIL FILTER LIGHT ON ENG. INSPECTION CK FOR WIND MILL AS PER M/M 72-00-00-6. CLOSED AND SECURED NR 2 PLATFROM AS PER M/M 53-00-00-2, NR2 COWLING CLOSED & INSPECTED AS PER MM 71-00-00-2. RII PLACING OIL FILTER BYPASS DETECTION SYSTEM INOP PRECAUTIONARY. C/W ENG.2 OIL FILTER INSPECTION PER MEL 79-30-1 A/C OK FOR SERVICE. RELEASED FOR SERVICE PER MEL: 79-30-01 R & R NR 2 OIL STRAINER CLOGGING SWITCH REF MD10 M.M. 79-35-01-2. LEAK CHECK NORMAL ENGINE RUN ALL INDICATIONS NORMAL.