FRAME AT STA 1280 HAS GOUGES BETWEEN AREAS OF STR 11R-17R. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07, FIG 101, DETAIL 2, P103; ORIGINAL MATERIAL IS .071", AFTER REWORK IS .050", LOSS IS .021". R & R FRAME SPLICE AT BS 1282, S12R-S13R, IAW SRM 53-00-07, FIG 201, REPAIR NR 3. BS 1280 FRAME, ITSELF, WAS FOUND TO BE WITHIN LIMITS IAW SRM 53-00-07, FIG 101, DETAIL 2. CAT "B" MAJOR REPAIR WITH THE FOLLOWING TRACKING; INITIAL AT 10,000 FC, THEREAFTER EVERY 12,000 FC, USING LFEC METHOD.