What was found
CAC COMPARTMENT FITTING AT THE PRESSURE DOME ADJACENT TO THE "SUGAR SCOOP" HAS A 2 IN CRACK IN THE LOWER LARGE RADIUS. (PN AYB7000-1) REMOVED CRACKED FITTING AND INSTALLED NEW FITTING PART NR AYB7000 IAW DWG NYB60472, SRM 51-31-01, SRM53-40-00. ACCOMPLISHED PART 3 OF EA WORK CARD T8-5340-121719 A P2, T8-5340-121719 A P3. REINSTALLED FASTENERS IN ARB 0323-1, REINSTALLED FASTENERS IN ARB 0322 IAW DWG NYB6042. REINSTALLED LONGERONS ADA 0158 AND ADA 0152 IAW SRM 51-31-01. INSTALLED BUSHING IN CORD NYS 6008 IAW CMM 20-20-07.