What was found
SECTION 44, FROM STA 1160-1180 BL0 UNABLE TO INSTALL PN 144N8006-211 INTERCOSTAL DUE TO EXISTING FASTNER HOLE 3EA LOCATIONS COMMON TO SKIN PANEL IF DRILLED WILL HAVE SHORT ED .385 IN THE INTERCOSTAL FIG "A" SECTION 44 FROM STA 1160-1180 BL0 PN 144N8006-211 INTERCOSTAL REPAIR WAS ACCOMPLISHED DUE TO DISCREPANCY IN THE PTF CONVERSION AREA . ON MAE MOD CARD 118350430EZR08 AND MAE EA 757-5345-16-F3090, REV- DATED JAN 6TH 2010. THIS N/R IS FOR TIME TRACKING PURPOSES ONLY AND CLASSIFIED A CATEGORY "A" MAJOR REPAIR. REF 8110-3, DATED MAR 28, 2011 FIRST STAGE APPROVAL,