What was found
REMOVED EXISTING REPAIR BS 324-340 STR. 22L TO 23L IAW SRM 51-40-02 AND INSTALLED REPAIR DOUBLER IAW SRM 53-00-01 FIG.201 REPAIR 15 THIS IS A CLASS "B" REPAIR WITH INSPECTION THRESHOLD OF 29,000 F/C AND REPEAT INSPECTION EVERY 6,000 F/C MAJOR REPAIR.