What was found
ON SHORT FINAL RECEIVED FUEL QTY/USED CK LEVEL 2 ALERT LANDED-CLEARED RUNWAY-HAD FIRE DEPT CK FOR LEAKS-NONE WERE SEEN-TAXIED TO BLOCKS. ONCE PARKED, ALERT CLEARED. EXPECTED FUEL QTY=24.4 ACTUAL FUEL QTY=23.6 RELEASED FOR SERVICE IAW MEL: 28-01-01 CATEGORY: A EXPIRATION: 15APR11 "MEL 28-01-01: TANK NR 2 FUEL QTY - INOP FUEL TO KNOWN QTY, AND AFTER REFUELING AND PRIOR TO EACH SUBSEQUENT DEPARTURE, VERIFY TANK NO 2 QTY WITH FUEL LEVEL STICKS AND RECORD IN THE AML/EAML. OPS NOT AUTHORIZED ABOVE 78 DEGREES N LAT. OPERATE FSC IN MANUAL." IAW MEL 28-01-01 NR 2 TANK FUELED TO KNOWN QTY AND FUEL QTY VERIFIED WITH FUEL LEVEL STICKS. STICK NRS AND STICK READINGS ARE RT AFT 14 LT AFT 14 AND FWD 7.5, FUEL QTY TNK 2 IS 22.4KLBS. ACFT OK SVC. SYS PLACED ON MEL 28-01-01.