What was found
AFTER T/O WHEN RETRACTING FLAPS FROM 2 TO 0 DEG NBR 2 SLAT LIGHT REMAINED ON. QRH ACTIONS ACCOMPLISHED AND LIGHTS REMAINED ON. RETURNED TO LAND. SLAT LIGHT EXTINGUISHED AFTER LANDING FOUND 4 OF THE 5 PINS PUSHED BACK IN CONNECTOR AT THE NR 2 SLAT ACTUATOR DISCONNECT. JUMPER NO HELP REMOVED JUMPER FROM CONNECTOR D0948 AND 2 PIN WERE PUSHED IN AGAIN AND 1 PIN PULLED OUT THROUGH SOCKET, R & R C/P FOR S199 SLAT SWITCH. SMP AND WDM 27-81-02. NEEDS OPS CHECKS. WHEN OPERATING SLATS, FOUND THAT GREEN EXTEND LIGHT STAYS ON ALL OF THE TIME. AMBER TRANSENT LIGHT NEVER COMES ON. DISCONNECTED PLUG D1114 AT EXTEND SWITCH AND JUMPERED PINS 5 & 6, AMBER LIGHT CAME ON. SWITCH S309 NEEDS REPLACED. 2 PANELS AT NR2 SLAT ARE REMOVED AND PLUG D1114 REMAINS DISCONNECTED. REF 727, WDM 27-81-02. R & R NR 2 SLAT POSITION INDCATION SWITCH IAW AMM 27-82-011-4. OPS CHECK OK IAW AMM 27-81-000-5. ACFT OK FOR SERVICE. (CLOSED)