What was found
DURING A CHECK, INSTALLED DOUBLER REPAIR AT STA.1500, STR 22L,FOUND S-22L CORRODED AROUND FASTENER HOLES AT STA 1510. CUT OUT DAMAGED STRINGER 22L BTW BS 1510 TO BS 1530 IAW SRM 53-00-03 REPAIR 2 PG 201, RECEIVED FABRICATED STRINGER, FABRICATED SPLICE HAT IAW SRM 53-00-03-1, INSTALLED THE REPAIR PARTS AND ACCOMPLISHED REPAIR SRM 51-40--2. MAJOR REPAIR.