What was found
LEFT WING SLAT NR 3, NR 9 TRACK BLEND OUT AREA EXCEEDED THE LIMITS (WIDTH=56.21MM). COMPLIED WITH EA 6-5741-103381, PART 3. REPLACED SLAT TRACK IAW AMM27-80-14-04. PERFORMED TEST OF SLAT IAW AMM27-80-14-04. TESTED OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT WING SLAT NR 3, NR 9 TRACK BLEND OUT AREA EXCEEDED THE LIMITS (WIDTH=56.21MM). COMPLIED WITH EA 6-5741-103381, PART 3. REPLACED SLAT TRACK IAW AMM27-80-14-04. PERFORMED TEST OF SLAT IAW AMM27-80-14-04. TESTED OK.