What was found
SEAT TRACK 3R HAS 8 EA AREAS OF CORROSION BETWEEN FRAMES 45-52, CORROSION EXIST ON FLANGES AS WELL AS SCALLOPS. MAX MEASURMENT OF ANY ON AREA IS 4 IN X .25 X .007. REMOVED CORROSION IAW SRM 51-74-10, PARA 6, AFTER REMOVAL OF LEVEL 1 CORROSION AREA OUT OF LIMITS. ORIGINAL THICKNESS .079, REMAINING THICKNESS .061 AND .060. FABRICATED NEW SEAT TRACK IAW DWG A538-12923, DRILLED SEAT TRACK IAW SRM 51-40-44 TABLE 3 AND 15, INSTALLED SEAT TRACK IAW SRM 51-40-26 PARA 5,6 &7.