What was found
WING CENTER TANK, UPPER SURFACE BS 940 STUB BEAM CORRODED. FOUND OUT OF LIMITS IAW SRM 53-00-51. NEW STUB BEAM FABRICATED IAW DWG 144N1019 AND FITTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WING CENTER TANK, UPPER SURFACE BS 940 STUB BEAM CORRODED. FOUND OUT OF LIMITS IAW SRM 53-00-51. NEW STUB BEAM FABRICATED IAW DWG 144N1019 AND FITTED.