As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CENTER TANK UPPER SKIN UPPER SURFACE FOUND CORRODED AT BS 920 , AT AREA JUST UNDER RT STUB BEAM CORROSION. REMOVED AND ASSESSED IAW SRM 57-10-01 MAX BLEND MATERIAL REMOVED 0.013 " MAX LIMIT 0.028" BLEND FOUND TO BE WITHIN LIMITS. DUE TO ACCUMALATIVE BLENDS IN AREA IN VARIOUS LOCATIONS IN CLOSE PROXIMITY IT IS INCORPORATED WITHIN EA F 5710-154331 BLENDED AND TREATED.