What was found
CABIN DOOR 3L SILL PLATE CREASE BEAM WEB HAS CORROSION ROUND FASTENER HOLES ON UNDERSIDE OF WEB. R & R IAW SRM 51-40-02, REV 104. REPAIR IS CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN DOOR 3L SILL PLATE CREASE BEAM WEB HAS CORROSION ROUND FASTENER HOLES ON UNDERSIDE OF WEB. R & R IAW SRM 51-40-02, REV 104. REPAIR IS CLASSIFIED AS MAJOR.