What was found
CABIN CREASE BEAM AT STA 1326 TO STA 1380, RBL 64 HAS CORROSION ROUND FASTENER HOLES ON UPPER AND LOWER CHORDS. R & R IAW SRM 51-40-02, REV 104. REPAIR IS CLASSIFIED AS MAJOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN CREASE BEAM AT STA 1326 TO STA 1380, RBL 64 HAS CORROSION ROUND FASTENER HOLES ON UPPER AND LOWER CHORDS. R & R IAW SRM 51-40-02, REV 104. REPAIR IS CLASSIFIED AS MAJOR.