What was found
R1 DOOR SLIDE REMOTE PRESSURE PRESS TO TEST INDICATING LIGHT INOPERATIVE. R & R R1 EVAC SLIDE PRESSURE TEST SYSTEM PER AMM 25-61-03-2-0. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
R1 DOOR SLIDE REMOTE PRESSURE PRESS TO TEST INDICATING LIGHT INOPERATIVE. R & R R1 EVAC SLIDE PRESSURE TEST SYSTEM PER AMM 25-61-03-2-0. OPS CHECKED GOOD.