What was found
LEFT WING (WING SIDE) OTBD FLAP, OTBD HINGE LOWER MOUNT OTBD HOLE FOUND CORRODED. REWORKED AND FOUND OUT OF LIMITS IAW CMM 57-44-09, REV 72. EXISTING HOLE DIA 0.585", FINAL HOLE DIA.0.597", MAX HOLE DIA 0.584". BUSHING FABRICATED AND INSTALLED AS IAW STEP 9 AND 10; WASHER FABRICATED AND INSTALLED IAW STEP 4 AND 11 OF EA 1-5750-150448. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 114.