What was found
LEFT WING (WING SIDE) OTBD FLAP OTBD HINGE LOWER MOUNT INBD HOLE FOUND CORRODED. REWORKED AND FOUND OUT OF LIMITS IAW CMM 57-44-09, REV 72. MAX ALLOWABLE DIA.0.584", EXISTING HOLE DIA 0.538", FINAL HOLE DIA 0.595", BUSHING FABRICATED AND INSTALLED IAW STEP 9 AND 10 OF EA 1-5750-150448, PART 1. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 114.