What was found
LEFT WING (WING SIDE) OTBD FLAP OTBD HINGE SIDE LOAD FITTING SURFACE FOUND CORRODED. REWORKED IAW REV 72 UPPER FACE EXISTING THICKNESS: 0.413", MATERIAL REMOVED :0.003", REMAINING THICKNESS :0.410", LOWER FACE EXISTING THICKNESS: 0.410", MATERIAL REMOVED :0.002" REMAINING THICKNESS: 0.408". REPAIR CARRIED OUT IAW EA 1-5750-150448 PART 1. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 114.