What was found
LEFT WING (WING SIDE) OTBD FLAP OTBD HINGE SIDE LOAD FITTING LOWER HOLE FOUND CORRODED. REWORKED AND FOUND OUT OF LIMITS IAW CMM 57-44-09, REV 72 EXISTING HOLE DIA. 0.398", FINAL HOLE DIA. 0.4095", MAX HOLE DIA. 0.391", BUSHING FABRICATED AND INSTALLED IAW STEP 9 AND 10 OF EA 1-5750-150448, PART 1. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 114.