What was found
RIGHT WING (WING SIDE) OTBD FLAP INBD HINGE SIDE LOAD FITTING SURFACE FOUND CORRODED. REWORKED IAW CMM 57-44-08, REV 72. EXISTING THICKNESS UPPER: 0.375", LOWER: 0.355", REMAINING THICKNESS UPPER: 0.365", LOWER: 0.345", MATERIAL REMOVED UPPER: 0.010", LOWER 0.010", REWORKED AREA PROTECTED IAW STEP 6 OF EA 1-5750-160003, PART 1. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 114.