What was found
RT WING (WING SIDE) OTBD FLAP OTBD HINGE LOWER MOUNT INBD HOLE FOUND CORRODED. REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09, REV 72 EXISTING HOLE DIA 0.582', FINAL HOLE DIA 0.598", MAX. ALLOWABLE DIA 0.584' REPAIR CARRIED OUT IAW EA 1-5750-150447, PART 1, STEP 3. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.