What was found
RT WING (FLAP SIDE) INBD FLAP OTBD HINGE OTBD PIVOT HOLE FOUND STEP HOLE. REPAIRED IAW EA 1-5750-160001, PART 1. EXISTING HOLE DIA.1.282" /1.192", MAX ALLOWABLE HOLE DIA 1.220". NEW BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-160001 PART 1, STEP 4 AND 5 . REPAIR CLASSIFIED MAJOR IAW 6-2-100, REV 114.