What was found
LT WING (FLAP SIDE) INBD FLAP OTBD HINGE INBD PIVOT HOLE FOUND STEP HOLE. MEASURED AND FOUND EXCEEDED LIMIT IAW CMM 57-52-03, REV 72 . EXISTING HOLE DIA 1.190", /1.253" , MAXIMUM HOLE DIA 1.220" BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-150446, PART 1 STEP 4 AND 5. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 114.