What was found
SHEAR TIE IS CRACKED AT FRAME BS 1300 BETWEEN S20L AND S21L. FABRICATED AND LOCATED AND DRILLED NEW SHEAR TIE IAW SRM 51-53-01. CRACK LENGTH 1.5". INSTALLED NEW SHEAR TIE, IAW SRM 51-40-02 AND DWG 140N2006. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SHEAR TIE IS CRACKED AT FRAME BS 1300 BETWEEN S20L AND S21L. FABRICATED AND LOCATED AND DRILLED NEW SHEAR TIE IAW SRM 51-53-01. CRACK LENGTH 1.5". INSTALLED NEW SHEAR TIE, IAW SRM 51-40-02 AND DWG 140N2006. MAJOR REPAIR.