What was found
GOUGES IN RT OTBD FLAP LOWER SKIN WS 500 CHECKED LIMITS AND FOUND TO BE OUT OF LIMITS IAW SRM 57-00-01, L=1.0" X W=.50" X D=.085". FABRICATED DOUBLER IAW SRM 57-10-00. INSTALLED DOUBLER IAW SRM 51-31-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GOUGES IN RT OTBD FLAP LOWER SKIN WS 500 CHECKED LIMITS AND FOUND TO BE OUT OF LIMITS IAW SRM 57-00-01, L=1.0" X W=.50" X D=.085". FABRICATED DOUBLER IAW SRM 57-10-00. INSTALLED DOUBLER IAW SRM 51-31-01.