What was found
LEFT WING OTBD FLAP, INBD FORWARD BRACKET SIDE ATTACH LOWER HOLE SPOT FACE FOUND CORRODED. REWORKED IAW CMM 20-11-02, REV 73. SHIM FABRICATED AND INSTALLED IAW CMM 57-44-08, REV 73. REPAIR EVALUATED AND FOUND SIDE LOAD MATING SURFACE REMAINING THICKNESS UPPER: 0.432"; LOWER: 0.430" WITHIN MINIMUM THICKNESS: 0.3685" BASED ON DIFFERENCE BETWEEN DWG ARCC0502 AND CMM 57-44-08 REV 73, MAXIMUM REWORK LIMIT FOR BARREL NUT HOLE. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100, REVISION 115.