What was found
EXTENDED MLG AT 8000 FT MSL/250KTS DURING CLIMBOUT DUE TO INCREASING BRAKE TEMP ON RT MLG. AFTER BRAKE TEMP STABILIZED, MLG WAS RETRACTED BEFORE SLOWING TO 230 KTS. NOSE GEAR LAST ONE TO STOW/LOCK DID NOT STOW LOCK UNTIL SLOW'G TO 240KTS. PERFORMED OPS TEST OF THE ANTISKID CONTROL UNIT IAW AMM32-45-01-5. TESTED NORMAL. PERFORMED THE A SCU R-T-S TEST AND ABS REQUIRED TEST. TESTED NORMAL. IAW AMM 32-48-00-5 AND AMM 32-45-00-5. PERFORMED OVERSPEED MLG INSPECTION ADN CHECK IAW AMM 05-51-07-6. CHECKED NORMAL. ACFT OK FOR SERVICE.