What was found
BS 1560, FRAME SPLICE CORRODED BETWEEN STR 24R AND 25R. REMOVED CORROSION AT FRAME SPLICE STA 1560 AT STR. 24 & 25R IAW-SRM-51-10-02. BLENDED AREA ORIG MAT .071, MAT REMAINING .034, NO ALLOWED DAMAGE ON SRM. R & R SPLICE IAW-SRM-51-40-02, FABRICATED SPLICE PLATE ON STAM TRAV T12/937656 AND DWG 146N042, CAT "A" MAJOR REPAIR.