What was found
MAIN CABIN BS 660 FLOORBEAM UPPER FWD FLANGE HAS ONE HOLE WITH SHORT ED LBL 69. OUT OF LIMITS IAW SRM 51-40-06, FIG 3. REMOVED FLOORBEAM IAW SRM 51-40-02. INSTALLED NEW FLOORBEAM IAW SRM 51-40-02 AND DWG 143N5012. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN BS 660 FLOORBEAM UPPER FWD FLANGE HAS ONE HOLE WITH SHORT ED LBL 69. OUT OF LIMITS IAW SRM 51-40-06, FIG 3. REMOVED FLOORBEAM IAW SRM 51-40-02. INSTALLED NEW FLOORBEAM IAW SRM 51-40-02 AND DWG 143N5012. MAJOR REPAIR.