What was found
JUST PRIOR TO LANDING, LEVEL 1 GEN 2 OFF, NR 2 IDG - INOPERATIVE AND DISCONNECTED. INTERROGATED EPCU, FOUND NR 2 IDG FEEDER/INTERFACE FAULT ON LAST FLIGHT LEG. CHECKED NR 2 IDG ALL FEEDER CABLES AND CONNECTORS. FOUND ONE ELECTRICAL CONNECTOR FREELY TURNED, THEN CLEANED AND RETIGHTENED, RECONNECTED IDG RAN ENG IAW JRH, NO HELP, NO VOLTAGE. EPCU CURRENT FAULTS SHOWN GCU-2 AND IDG-2 FEEDER/INTERFACE.