What was found
RT WING AT STATION 806.50, AILERON B. WIRE ATTACHMENT POINT CORRODED. REMOVED CORROSION IAW SRM 51-10-02, CHECKED LIMITS ORIGINAL MATERIAL .070, MATERIAL REMAINING .040, MATERIAL LOSS .030. FOUND OUT OF LIMITS IAW SRM 57-51-09, PG 106, DETAIL IV, FIG.101. REMOVED AND REPLACED RIB IAW SRM 51-40-02, 51-40-05, AND DRAWING 113N1511. MAJOR REPAIR