As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFTER EXTENDING THE LANDING GEAR FOR LANDING. LANDING GEAR "DOORS" LIGHT DID NOT EXTEND. R & R DOWNLOCK VALVE PER AMM 32-32-07-4. MAIN GEAR DOWNLOCK, OPERATED DOOR SEQUENCE PERFORMED CHECK OF THE UPLOCK OPERATE SEQUENCE VALVE PER SUBTASK 32-32-09-864-014.TEST SATISFACTORY AND PERFORMED CHECK OF SAFETY VALVE PER AMM 32-35-05-864-018. ALL TEST SATISFACORY NO HYD LEAK DETECTED. ACFT OK FOR SERVICE.