As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK FLOORBEAM BS 660 CAME SHORT AT LT END TO PICK UP CREASE BEAM OTBD CHORD FASTENER HOLE. REMOVED SHORT FLOORBEAM IAW SRM 51-40-02 & DWG 143N5012 SH 19. FABRICATED NEW FLOORBEAM IAW DWG 146N5012, SH 19, INSTALLED NEW FLOORBEAM IAW SRM 51-40-02 & DWG 143N5430, PAGE 23 AT STA. 660. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR.