What was found
FOUND LT WING RIB NR 5 HOLE NR 52 ALREADY 2ND OVERSIZE FASTENER HOLE. PERFORMED OVERSIZE THE SUBJECT HOLE TO DIAMETER OF 0.8075" TO 0.8095" IAW EO 6-5710-7-3325. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND LT WING RIB NR 5 HOLE NR 52 ALREADY 2ND OVERSIZE FASTENER HOLE. PERFORMED OVERSIZE THE SUBJECT HOLE TO DIAMETER OF 0.8075" TO 0.8095" IAW EO 6-5710-7-3325. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100.