What was found
FLOORBEAM AT BS 1661 UPPER TEE TOP AND UNDERSIDE HAS SEVERAL AREAS WITH SCRATCHES, GOUGES, AND CORROSION. R & R FLOORBEAM IAW SRM 51-40-01 AND DWG 146N5090-16. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM AT BS 1661 UPPER TEE TOP AND UNDERSIDE HAS SEVERAL AREAS WITH SCRATCHES, GOUGES, AND CORROSION. R & R FLOORBEAM IAW SRM 51-40-01 AND DWG 146N5090-16. MAJOR REPAIR.