What was found
MAIN CABIN FLOOR STRUCTURE CLEVIS ADAPTER AT FR 58 BETWEEN SEAT TRACKS 2R AND 3R, HAS CORROSION INSIDE OF TRACK. REMOVED LEVEL 1 CORROSION ON CLEVIS ADAPTER AT FR 58 BETWEEN SEAT TRACK 2R AND 3R IAW FSRM 51-74-10, PG 205, PARA 3. FOUND THE CLEVIS ADAPTER TO BE OUT OF LIMITS FSRM 53-10-15, PG 104. R & R CLEVIS ADAPTER AT FR 58 BETWEEN SEAT TRACK 2R AND 3R IAW FSRM 51-40-20 AND 51-72-10. REPROTECTED AREA IAW FSRM 51-75-10, PG 203 AND 204.