What was found
ON POST FLIGHT CHECK FOUND NR 3 AVIONICS RACK COOLING BREAKER POPPED. RESET BREAKER AND IT POPPED AGAIN. REMOVED DAMAGED WIRING AND REPAIRED FOLLOWING WIRES. B115-280-14B,B115-12-14C,B115-281-14C,B115-283-14B, B115-284-14C,B115-282-14A,B115-42-12,B115-276-14B, B115-41-12,B115-10-14A WITH SPLICES PER SWPM 20-10-03. CHECKED ALL AFFECTED WIRING FOR INTEGRITY AND OPERATION. ACCOMPLISHED WIRE BUNDLE REROUTE OF ABS9115 AND ABS9102 PER E.A 8-2126-166275.