What was found
MAIN DECK FRAME BS 1140 HAS A DOUBLE DRILLED HOLE BETWEEN S-2R & S-3R (INCOMING CONDITION). REMOVED DAMAGED AREA OF FRAME STA 1140 BETWEEN S-2R AND S-3R IAW SRM 51-10-02, SRM 53-00-07, REPAIR 3. FABRICATED REPAIR CHANNELS AND FILLER IAW SRM 53-00-07 FIG 201 TABLE I. DRILLED AND LOCATED -1, -2, CHANNEL, AND -3 FILLER IAW SRM 51-40-05. INSTALLED REPAIR CHANNELS -1, -2, AND -3 FILLER IAW SRM 51-40-02 , AND SRM 53-00-07 REPAIR 3. MAJOR REPAIR.