What was found
MAIN DECK FLOORBEAM AT BS 1640, LBL 30-LBL 60 HAS CORROSION ON LOWER SKIN UNDER NUTCLIP HOLES. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL VI. R & R FLOORBEAM BS 1640 IAW SRM 51-40-02 AND DWG 146N5089. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOORBEAM AT BS 1640, LBL 30-LBL 60 HAS CORROSION ON LOWER SKIN UNDER NUTCLIP HOLES. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DETAIL VI. R & R FLOORBEAM BS 1640 IAW SRM 51-40-02 AND DWG 146N5089. MAJOR REPAIR.