As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN DECK CREASE BEAM ANGLE NUT PLATES-MOUNTING HOLES OVERSIZE DUE TO CORROSION AT BS 1000-1040, RT SIDE. FOUND TO BE OUT OF LIMITS IAW SRM 53-40- 13 FIG 101 DETAIL III. FABRICATED NEW ANGLE. LOCATED AND DRILLED IAW DRAWING 144N5152. AND INSTALLED IAW SRM 51-40-02 AND DRAWING 144N5152. MAJOR REPAIR