As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT PIT BILGE AREA BETWEEN STA 1600-STA 1620, STRINGER 27R, CORRODED. REMOVED STRINGER SPLICE IAW SRM 51-40-02. REMOVED CORROSION IAW SRM 51-10-02. FOUND OUT OF LIMITS IAW SRM 53-00-53 FIG 101 DETAIL V. FABRICATED SPLICE. LOCATED AND DRILLED IAW SRM 51-40-05. INSTALLED IAW SRM 51-40-02 AND DWG 146N3820. MAJOR REPAIR