Service difficulty report · Valve · Airbus A310222

Difficulty date
March 13, 2013
Submitted
March 18, 2013
Operation
Air carrier
Aircraft
N455FE
Make and model
Airbus A310222
Aircraft serial
331
Aircraft time
37,853 hours, 17,683 cycles
Part
Valve
Part number
A2519903
Part serial
FEC8087
Condition
Malfunctioned
Location
Mlg
Stage of operation
AP
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LANDING GEAR FAILED TO EXTEND IN POSITION NR 1 OR NR 2. COMPLIED W/ QRH - MANUAL EXTENSION OK. EMERGENCY DECLARED. T/S IAW TSM 32-61-00. PREFORMED BITE TEST PROX DET. BOX FOUND FAULT CODES P2, P4. (EXTERNAL PWR SUPPLY BUS). IAW MM 32-33-00-02 RESTORED FREEFALL EXTENSION SYS TO NORMAL OPERATING CONDITION. GEAR DOORS CLOSED AND GEAR PINS INSTALLED. GEAR PINS REMOVED AND STOWED IN COCKPITS FOR FLIGHT. CHECKED WIRING AT LANDING GEAR SELECTOR VALVE REF AWM 32-31-01. ALL CHECKS NORMAL. R & R ELECTRO HYD VALVE 3GA REF MM 32-31-12-04. VALVE LEAKS CHECKS GOOD. PERFORMED OPS/INSPECTION CHECK REF MM 32-31-12-06. OPS CHECK OF GEAR AND LIGHTS NORMAL.