What was found
BS 1640 MULTUIPLE AREAS OF CORROSION FOUND FLOORBEAM STRUCTURE ON THE UPPER SURFACE AND UNDERSIDE SURFACE. CORROSION REMOVED IAW SRM 51-10-02 REV 108. FOUND EXCEED LIMITS IAW SRM 53-00-51 ALLOWABLE DAMAGE1 FIG 101 REV 108. FLOORBEAM REMOVED IAW SRM 51-40-02 REV 108. NEW FLOORBEAM FABRICATED IAW DWG 146N5109 SHT 1 REV A AND INSTALLED IAW DWG 146N5089 SHT 1 REV B AND COMPLIED WITH EA F-5310-166057. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100