What was found
MAIN DECK FLOORBEAM BS 1681 UPPER TEE FROM RBL 60 TO LBL 60 HAS SEVERAL AT THE LOWER SURFACE CORRODED. FOUND OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DET III. R & R FLOORBEAM IAW SRM 51-40-02 AND DWG 146N5091. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOORBEAM BS 1681 UPPER TEE FROM RBL 60 TO LBL 60 HAS SEVERAL AT THE LOWER SURFACE CORRODED. FOUND OUT OF LIMITS IAW SRM 53-00-51, FIG 101, DET III. R & R FLOORBEAM IAW SRM 51-40-02 AND DWG 146N5091. MAJOR REPAIR.