What was found
MAIN DECK FLOORBEAM BS 377 HAS CORROSION ON UPPER TEE, LBL 12 -BL 0. FLOORBEAM REMOVED IAW SRM 51-40-02, REV 108 AND NEW FLOORBEAM INSTALLED IAW DWG 141N5113, SHT 1, REV F. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOORBEAM BS 377 HAS CORROSION ON UPPER TEE, LBL 12 -BL 0. FLOORBEAM REMOVED IAW SRM 51-40-02, REV 108 AND NEW FLOORBEAM INSTALLED IAW DWG 141N5113, SHT 1, REV F. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.