What was found
FLOORBEAM TEE BS 1641 AND RBL 48-54 CORRODED. . FLOORBEAM WAS R & R IAW DWG 146N5109, SHT1, REV A AND 146N5089 SHT1 REV B. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.