What was found
S-17R, BS 1405 - 1630, CREASE BEAM INBD ANGLE CORRODED. BLENDED IAW SRM 51-10-02, CHECKED AND FOUND TO BE OUT OF LIMITS IAW SRM 51-6-13 PG 105 DET VIII. REMOVED AND REPLACED INBD ANGLE IAW SRM 51-40-02 AND DWG 146N5590. MAJOR REPAIR
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
S-17R, BS 1405 - 1630, CREASE BEAM INBD ANGLE CORRODED. BLENDED IAW SRM 51-10-02, CHECKED AND FOUND TO BE OUT OF LIMITS IAW SRM 51-6-13 PG 105 DET VIII. REMOVED AND REPLACED INBD ANGLE IAW SRM 51-40-02 AND DWG 146N5590. MAJOR REPAIR