What was found
LT MLG DOOR UPLOCK FREE FALL INPUT ROD FOUND TO BE WIRED TO UPLOCK IN CLOSED POSITION THROUGH RIGGING PIN HOLE. CARRIED OUT UPLOCK FREEFALL INPUT ROD REMOVED CABLE CONNECTION AND RIG CHECK AND FOUND TO BE CORRECT. MANUAL GROUND DOOR OPENING AND CLOSING TEST CARRIED OUT AND FREEFALL DOOR OPENING TEST CARRIED OUT SATISFACTORY IAW AMM 32-31-36-09, 32-12-11 PB 30, 32-33-00, PB 501, PARA 2D.